voestalpine Böhler Welding Austria GmbH uses cookies in order to provide you with the best possible service. By continuing to use this site you consent to the use of cookies.
Covered electrodes for cladding (anti-corrosion) applications
UTP Maintenance offers a full range of covered electrodes for anti-corrosion (cladding) applications.
Product Name | EN/EN ISO | AWS |
---|---|---|
UTP 759 KB | EN ISO 14172 / E Ni 6059 (NiCr23Mo16) | AWS A5.11 / ENiCrMo-13 |
UTP 776 KB | EN ISO 14172 / ENi6276(NiCr15Mo15Fe6W4) | AWS A 5.11 / ENiCrMo-4 |
UTP 4225 | EN ISO 2560-A / E 42 3 B 32 H10 | AWS A5.1 / E 7018 |
UTP 6222 MO | EN ISO 14172 / E Ni 6625 (NiCr22Mo9Nb) | AWS A 5.11 / E NiCrMo-3 |
TIG rods for cladding (anti-corrosion) applications
UTP Maintenance offers a full range of TIG rods for anti-corrosion (cladding) applications.
Product Name | EN/EN ISO | AWS |
---|---|---|
UTP A 759 | EN ISO 18274 / S Ni 6059 (NiCr23Mo16) | AWS A5.14 / ER NiCrMo-13 |
UTP A 776 | EN ISO 18274 / S Ni 6276 (NiCr15Mo16Fe6W4) | AWS A5.14 / ERNiCrMo-4 |
UTP A 4221 | EN ISO 18274 / S Ni 8065 (NiFe30Cr21Mo3) | AWS A5.14 / ERNiFeCr-1 |
UTP A 6222 MO | EN ISO 18274 / S Ni 6625 (NiCr22Mo9Nb) | AWS A5.14 / ER NiCrMo-3 |
Solid wires for cladding (anti-corrosion) applications
UTP Maintenance offers a full range of solid wires for anti-corrosion (cladding) applications.
Product Name | EN/EN ISO | AWS |
---|---|---|
UTP A 786 | EN ISO 18274 / S Ni 6686 (NiCr21Mo16W4) | AWS A5.14 / ER NiCrMo-14 |
UTP A 4221 | EN ISO 18274 / S Ni 8065 (NiFe30Cr21Mo3) | AWS A5.14 / ERNiFeCr-1 |
UTP A 6222 MO | EN ISO 18274 / S Ni 6625 (NiCr22Mo9Nb) | AWS A5.14 / ER NiCrMo-3 |
UTP A 6222 MO-3 | EN ISO 18274 / S Ni 6625 (NiCr22Mo9Nb) | AWS A5.14 / ERNiCrMo-3 |
Gas shielded cored wires for cladding (anti-corrosion) applications
UTP Maintenance offers a full range of gas shielded core wires for anti-corrosion (cladding) applications.
Product Name | DIN | HB | HRC | C | Mn | Si | Cr | Ni | Mo | Nb | Ti | W | V | Fe | Cu | Low stress abrasion | Impact | Corrosion | Cavitation | Metal to metal wear | Heat |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SK 307-G | DIN 8555 / MF 8-GF-150-KP | 155 |
| 0.1 | 7.1 | 0.8 | 17.9 | 8.5 |
|
|
|
|
| Bal. | 2,0 |
|
| x |
| x |
|
SK 356-G | DIN 8555 / MF 4-GF-50-ST |
| 47 | 0.7 | 1.2 | 0.9 | 12 | 0.7 | 3.8 |
|
| 0.9 | 2 | Bal. |
| x | x |
|
| x |
|
SK 402-G | DIN 8555 / MF 8-GF-150-KP | 170 |
| 0.1 | 6.6 | 0.6 | 17.1 | 7.8 |
|
|
|
|
| Bal. |
|
| x |
|
|
|
|
SK 410 C-G | DIN 8555 / MF 5-GF-40-C |
| 40 | 0.08 | 0.7 | 0.4 | 13 |
|
|
|
|
|
| Bal. |
|
|
| x |
| x |
|
SK 420 Mo-G | DIN 8555 / MF 6-GF-55-C |
|
| 0.24 | 1 | 0.4 | 12 |
| 0.7 |
|
|
|
| Bal. |
|
| x |
| x |
| |
SK 430-G | DIN 8555 / MF 5-GF-200-C | 190 |
| 0.06 | 0.8 | 0.6 | 17.8 |
|
|
| 0.2 |
|
| Bal. |
|
|
| x |
|
|
|
SK 430 MO-G | - / - | 260 |
| 0.25 | 1 | 0.6 | 19 |
| 0.9 |
|
|
|
| Bal. |
|
|
| x |
|
|
|
SK 519-G | DIN 8555 / MF 8-GF-C |
|
| 0.02 | 2.8 | 0.5 | 20.5 | 24.2 | 5 | Other: N = 0.12 |
|
|
| Bal. | 1,1 |
| x | x |
|
|
|
SK 741-G | DIN 8555 / MF 5-GF-40-C |
| 41 | 0.06 | 0.5 | 0.6 | 13 | 5.5 | 0.8 |
|
|
|
| Bal. |
|
|
| x |
| x |
|
SK 768-G | DIN 8555 / MF 5-GF-350-C | 0.02 | 0.3 | 0.3 | 14.5 | 6.3 | 2.5 |
|
|
|
| Bal. |
|
| x |
| x |
| |||
SK ANTINIT DUR 290 | DIN 8555 / MF 9-GF-250-CT | 250 |
| 0.06 | 1.9 | 5.6 | 17 | 8.3 |
|
|
|
|
| Bal. |
|
|
| x | x | x | x |
SK ANTINIT DUR 500 | DIN 8555 / MF 9-GF-45-CT |
| 43 | 0.07 | 4.3 | 4.5 | 17.5 | 8 | 5.4 | 1 |
|
|
| Bal. |
|
|
| x | x | x | x |
Open arc cored wires for cladding (anti-corrosion) applications
UTP Maintenance offers a full range of open arc cored wires for anti-corrosion (cladding) applications.
Product Name | DIN | HB | HRC | C | Mn | Si | Cr | Ni | Mo | Nb | Ti | W | V | Fe | Cu | Low stress abrasion | High stress abrasion | Erosion | Impact | Corrosion | Cavitation | Metal to metal wear | Heat |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SK 370-O | DIN 8555 / MF 5-GF-400-C |
| 42 | 0.03 | 0.5 | 0.6 | 15.5 | 5.2 | 0.5 |
|
|
|
| Bal. |
|
|
|
|
| x |
| x | x |
SK 402-O | DIN 8555 / MF 8-GF-150/400-KPZ | 160 |
| 0.09 | 6 | 0.9 | 18 | 7.8 |
|
|
|
|
| Bal. |
|
|
| x |
| x |
|
|
|
SK 420-O | DIN 8555 / MF 6-GF-55-C |
| 54 | 0.4 | 0.7 | 0.2 | 13.5 |
| 0.2 |
|
|
|
| Bal. |
|
|
|
|
| x |
| x |
|
SK 430-O | DIN 8555 / MF 5-GF-250-C | 260 |
| 0.04 | 0.9 | 0.2 | 17 |
|
|
|
|
|
| Bal. |
|
|
|
|
| x |
|
|
|
SK 714 N-O | DIN 8555 / MF 5-GF-45 |
| 44 | 0.03 | 1 | 0.6 | 13 | 4.2 | 0.5 | Other: N = 0.10 |
|
|
| Bal. |
|
|
|
|
| x |
| x |
|
SK 741-O | DIN 8555 / MF 5-GF-45-C |
| 43 | 0.02 | 0.6 | 0.6 | 12.6 | 5.2 | 0.8 |
|
|
|
| Bal. |
|
|
|
|
| x |
| x | x |
SAW cored wires for cladding (anti-corrosion) applications
UTP Maintenance offers a full range SAW cored wires for anti-corrosion (cladding) applications.
Product Name | DIN | HB | HRC | C | Mn | Si | Cr | Ni | Mo | Nb | W | V | Fe | Co | N | Erosion | Impact | Corrosion | Cavitation | Metal to metal wear | Heat |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SK 385-SA | DIN 8555 / UP 6-GF-55-CG |
| 54 | 0.3 | 1.3 | 0.4 | 16 |
| 0.5 |
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 402-S | DIN 8555 / UP 8-GF-150/400-KPZ | 150 |
| 0.07 | 6.6 | 1 | 17 | 8 |
|
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 410 NIMO-SA | DIN 8555 / UP 5-GF-40-C |
| 39 | 0.05 | 1 | 0.3 | 12.5 | 5 | 0.9 |
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 415-SA | DIN 8555 / UP 5-GF-45-C |
| 42 | 0.08 | 0.9 | 0.4 | 13.5 | 2.1 | 1.1 | 0.2 |
| 0.3 | Bal. |
|
|
|
|
|
|
|
|
SK 420-SA | DIN 8555 / UP 6-GF-55-CG |
| 53 | 0.27 | 1.3 | 0.3 | 13.5 |
|
|
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 430 C-SA | DIN 8555 / UP 5-GF-200-C | 260 |
| 0.25 | 1 | 0.6 | 17.9 |
| 1 |
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 430 MO-SA | DIN 8555 / UP 6-GF-300-C | 175 |
| 0.04 | 0.9 | 0.5 | 19.5 |
|
|
|
|
| Bal. |
|
|
|
|
|
|
|
|
SK 461-CSA | DIN 8555 / UP 6-GF-50-C |
| 54 | 0.26 | 0.9 | 0.5 | 12.2 | 0.4 | 1.4 |
| 0.9 | 1 | Bal. | 1.8 |
|
|
|
|
|
|
|
SK 742 N-SK | DIN 8555 / UP 5-GF-45-C |
| 44 | 0.04 | 1.2 | 0.4 | 13.5 | 3.3 | 1.3 | 0.1 |
| 0.15 | Bal. |
|
|
|
|
|
|
|
|
STRIPS and FLUXES for strip cladding (anti-corrosion) applications
UTP Maintenance offers a full range of Soudotape strips and RECORD agglomerated fluxes for submerged arc and electroslag strip cladding for anti-corrosion applications.
Visit our Product Search.