Open preview picture of file
VS60 / VS60H
VS60 (magnetic drive)
End position damping guarantees quiet and gentle setting of the turnout. The whole system is designed modularly and the clear and open structure provides good accessibility of all components that relief inspection and maintenance works. All components are well-chosen and the functional design guaranties maximum availability and longest inspection and maintenance intervals. These are factors to consider in optimised Life Cycle Costs (LCC) to achieve the best system efficiency.
Meeting the requirements of the modern urban transport, the setting device VS60 fulfills the highest safety standards and it is proven according to CENELEC (SIL3/Safety Integrity Level 3 by EN 50126/EN 50129).
VS60 H (hydraulic drive)
Advantages
- Trailable without damage
- Full lock (locking of operating and detector rods)
- 6-fold inductive detection of end position of the switches
- Low height of ground box (max. 340 mm)
- Lowest maintenance (every 6 month operational check, every 12 month small service, general overhaul every 8 year or after 1,000,000 settings)
- Little wear because of high-quality material
- Use of wear-resistant guides (no linear guides)
- Contamination resistant
- Modular design (driving system is easily exchangeable)
- Good accessibility of all modules and components
- Rods can be easily separated from mechanism by connecting pins
- Quick assembly, adjustment required only
- Insulated type available
- Damping (low-noise, gentle setting)
- Electric components placed in IP67/IP68
protected housing - Interface to control unit by means of special terminal box
- SIL3 approved according to EN50126/EN50129
Technical characteristics:
| GENERAL: | |
| Gauge | from 1000 mm |
| Stroke of switch | adjustable from 35 – 70 mm |
| Tongue attachment of operating rods | as per customer specification |
| Tongue attachment of detection rods | as per customer specification |
| Operating force of rods | ca. 4000 N |
| Trailing force | ca. 1000 N |
| Retaining force of spring mechanism to switches | ca. 1300 to 2200 N |
| Moment of manual operation | ca. 150 bis 250 Nm |
| Damping | Damper Self-damping of the system |
| Setting time | 0.5 to 2 sec, depending on switch stroke and damping effect |
| Operating temperature range | -40° to +85°C |
| Max. axle load on ground box cover | 12 kN |
| Electronic detection | 6 inductive detection elements 24 V DC |
| Gauge of 1435 mm: | Gauge of 1000 mm: | |
| Height | 340 | 340 |
| Width | 1220 | 815 |
| Depth | 1125 | 850 |
| Total weight VS60 | ca. 650 kg | ca. 610 kg |
| Total weight VS60 H | ca. 600 kg | ca. 560 kg |
| Max. weight of ground box cover | ca. 65 kg | ca. 50 kg |
VS60 mechanic schema
Main dimensions of VS60 / VS60 H