Full Length NDT Inspection

Flux Leakage Testing with Integrated Wall Thickness Testing

Technical data

manufacturer Institut Dr. FÖRSTER (wall thickness system: GE Inspection Technologies)
type Rotomat - IDC RO 310 DS [FT], Transomat - TR 310 DS [FT], ROWA 160 & 230 VIS [UT]
system Longitudinal and transverse flaw inspection with "Flux Leakage technologies"; wall thickness verification with "UT Phased array technology"
detection capabillity Longitudinal and transverse flaws on the outside and inside surface; wall thickness verification
outside diameter range 40 – 200 mm (1.575 - 7.874 in)
including pipes with upset ends
inspection speed max. 2 m/sec (6.6 ft/sec)

 

Magnetic Particel Inspection of pipe ends

Technical data

manufacturer TIEDE
system pipe ends are magnetized using direct-current coils; additional alternating-current magnetic flux, wet fluorescence magnetic powder
detection capabillity flaws in any direction on the outside and inside surface
outside diameter range 40 – 200 mm (1.575 - 7.874 in)
including pipes with upset ends
coverage distance max. 305 mm (12 in)